IP2395EN
5. Ditec DOD14 chain link-up installation
NOTE: DODT - Drive shaft with Z24 pinion and key
3Gx1.5 mm²
3x0.5 mm² (limit switch)
4Gx1.5 mm² (motor)
DOD14
CAT1+
CAT G
DODT
LCA85
LCA85B
ATTENZIONE: corona non di
nostra fornitura
Type Pinion Crown
Reduction
ratio
Torque
[Nm]
Rotating
speed
[RPM]
Door cable
pulley
[Ø mm]
Door
speed
[m/s]
Max Run
[m]
Max force
[N]
DOD 14
DODT
1/2”x5/16”
Z= 24
1/2”x5/16”
Z= 30
1:1,25 75 17,6
102
124
158
226
Ø
0,09
0,11
0,15
0,21
= Ø:1085
7,0
8,5
10,8
15,5
= Ø:14.57
1470
1210
949
664
=150000:Ø
DODT
1/2”x5/16”
Z= 24
1/2”x5/16”
Z= 39
1:1.625 97.5 13.5
102
124
158
226
Ø
0.07
0.09
0.11
0.16
= Ø:1410.5
5.4
6.5
8.3
11.9
= Ø:18.95
1912
1573
1234
863
=195000:Ø
DODT
1/2”x5/16”
Z= 24
1/2”x5/16”
Z= 45
1:1.875 112.5 11.7
102
124
158
226
Ø
0.06
0.08
0.10
0.14
= Ø:1627.5
4.7
5.7
7.2
10.3
= Ø:21.86
2206
1815
1424
996
=225000:Ø