EasyManua.ls Logo

DLS FlexxPump 125 B - Factory Settings; Default Settings Operating Mode Hour-Mode -H

DLS FlexxPump 125 B
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
revision: 1
FlexxPump 125 B
User Manual
19
EN-
SCHMIERSYSTEME
DIRECT LUBRICATION SYSTEMS
D L S
6.2 Factory settings
FlexxPump 125 B is always delivered ex works with the following settings:
operating mode Hour-Mode -h-
Mode OFF FlexxPump 125 B is switched off
The factory settings foresee using the FlexxPump 125 B in the Hour-Mode -h-. If
you want to operate the FlexxPump 125 B in Empty-Time-Mode Et, you have to make
changes in the SET-Menu of the FlexxPump 125 B to set the Empty-Time-Mode Et
(chapter 6.3.6).
Dispensing time h = 6 The dispensing time is 6 hours.
Number of cycles c = 1 The number of cycles is one (1) stroke
during the dispensing time.
The default settings in the Hour-Mode result in an emptying time (service life) of 195
days (= 6.4 months) for a full 125 ml lubricant cartridge, provided that the FlexxPump
125 B is permanently switched on and no special dispensations have been made.
Within approx. 6 hours, the FlexxPump 125 B will deliver one donation per stroke
(0.15 cm³).
Verify that the default settings are appropriate for your application and that the
lubrication point is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the FlexxPump 125 B with the default settings in the
Hour-Mode -h-.
If this is not the case, change the values for the dispensing time t and number of cycles
c accordingly; see chapter 6.3.8 for an explanation of how to make these changes.
To use FlexxPump 125 B, it must first be properly mounted and installed and then
switched on. Installation is very simple and described in detail in chapter 5.2; switching
on is described in chapter 6.3.3.
If you order a special version of FlexxPump 125 B from the factory, the information
contained in the supplement is authoritative for you!
6.2.1 Default settings operating mode Hour-Mode -h-