revision: 1
FlexxPump 125 B
User Manual
20
EN-
SCHMIERSYSTEME
DIRECT LUBRICATION SYSTEMS
D L S
Emptying time Et = 6 The emptying time of one (1) cartridge is 6 months.
The default settings in the Empty-Time-Mode result in an emptying time (service
life) of 6 months for a full 125 ml lubricant cartridge, provided that the FlexxPump 125
B is permanently switched on and no special dispensations have been made. Within
approx. 5.6 hours, the FlexxPump 125 B will deliver one donation per stroke (0.16 cm³).
Verify that the default settings are appropriate for your application and that the
lubrication point is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the FlexxPump 125 B with the default settings in the
Empty-Time-Mode Et.
If this is not the case, change the values for the emptying time t accordingly; see
chapter 6.3.9 for an explanation of how to make these changes.
To use FlexxPump 125 B, it must first be properly mounted and installed and then
switched on. Installation is very simple and described in detail in chapter 5.2; switching
on is described in chapter 6.3.3.
If you order a special version of FlexxPump 125 B from the factory, the information
contained in the supplement is authoritative for you!
6.2.2 Default setting operating mode Empty-Time-Mode Et