revision: 1
FlexxPump 125 B
User Manual
43
EN-
SCHMIERSYSTEME
DIRECT LUBRICATION SYSTEMS
D L S
Clean the FlexxPump 125 B from dirt using suitable cleaning agents (e.g. absorbent
towels, cloths).
NOTICE
Compressed air can damage the seals of the FlexxPump 125 B
as well as transport dirt and foreign bodies into the FlexxPump
125 B or the lubricant.
§ Do not use compressed air to clean the FlexxPump 125 B.
7.1.1 Visual check
Reinstall all safety devices and make sure that no tools remain in the danger area.
Check that the FlexxPump 125 B is turned on.
Carry out a "Quick Check" (test run) using the RUN command (section 6.3.7).
Check the entire lubrication system (FlexxPump 125 B and any connected
accessories including tubes and distributors) for external damage (e.g. loose or
loosened tubes) by a thorough and conscientious visual inspection.
Check the condition of the lubrication point for correct supply of lubricant.
Replace damaged or defective parts immediately to ensure permanent lubrication.
Check the filling level of the cartridge on the FlexxPump 125 B.
Check possible error messages on the FlexxPump 125 B and remedy the causes
accordingly.
7.1.2 Cleaning
7.1.3 Recommissioning after maintenance