revision: 1
FlexxPump 125 B
User Manual
44
EN-
SCHMIERSYSTEME
DIRECT LUBRICATION SYSTEMS
D L S
7.2 Cartridge and battery change
Changing the lubricant cartridge of the FlexxPump 125 B is very easy and takes place
in four steps.
In the present version of a battery-powered FlexxPump 125 B, in addition to changing
the cartridge, the battery has to be changed at the same time. The cartridge only needs
to be changed if it is empty, the battery is empty or the service life of the lubricant has
been exceeded. The cartridge and battery can be changed during normal operation of
the FlexxPump 125 B.
FlexxPump 125 B has a fault (Error E1 or Error E3); the red LED flashes every 5
seconds.
OR
The FlexxPump 125 B battery is completely discharged, the LCD is dark (OFF is not
displayed).
NOTICE
A used lubricant cartridge must not be replaced on the
FlexxPump 125 B, as the integrated stroke counter of the
FlexxPump 125 B is automatically reset by the cartridge sensor
after a cartridge has been removed.
§ Only use full lubricant cartridges.
NOTICE
Only use original lubricant cartridges with lubricant approved
by the manufacturer.
§ Observe the maximum shelf life of lubricant lled in cartridges.
NOTCE
It is not possible to rell empty or opened lubricant cartridges.
NOTICE
Make sure you use the same lubricant in the new cartridge that
is already in use.
§ Compare the data on the lubricant cartridge.
The battery of the FlexxPump 125 B must be replaced at the
same time as the lubricant cartridge!