Digital Monitoring Products, Inc. | Troubleshooting Guide 35
SYSTEM MESSAGES WITHOUT RESTORAL
System messages should include 00 for area - AA and 000 for loop number - ZZZ� Except Abort by User (s050) should
include the user number - ZZZ� The Qualifier should be 1 for all messages�
DMP PANEL MESSAGE SUB-MESSAGE CID CODE DEFINITION
AUTOMATIC RECALL TEST 07 602 TEST - Periodic
AMBUSH 15 121 PANIC - Duress
SYSTEM TEST 23 601 TEST - Manually Triggered
ABORT SIGNAL 4 5/49 406 OPENING - Cancel - User ZZZ
UNSUCCESSFUL REMOTE CONNECTION 54 413 REMOTE - Unsuccessful Access
EARLY TO CLOSE 75 451 Early O/C
LATE TO OPEN 76 453 Failed to Open
UNAUTHORIZED ENTRY 77 450 Exception to O/C
SYSTEM RECENTLY ARMED 78 459 TROUBLE - Recent Close
EXIT ERROR 80 457 CLOSING - Exit Error
REMOTE PROG. COMPLETE 83 412 REMOTE - Successful Access
TRANSMIT FAIL 87 354 TROUBLE - Fail to Communicate
LOCAL PROGRAMMING 86 458 Operator on Premises
AUTOMATIC RECALL TEST 88 608 TEST - Periodic (Unrestored System)
ALARM: VERIFY SIGNAL RECEIVED 96 139 Intrusion Verifier
PANEL RESTART 109 305 System Reset
SYSTEM MESSAGES WITH RESTORAL
System messages should include 00 for area - AA and 000 for loop number - ZZZ, except for Device Missing, which
should include the address in the loop number digits� The loop number for the Cell Comm Bus Fail/Rst messages should
be 000� The Qualifier should be 1 for trouble, burglary or begin test and 3 for restore or end test�
DMP PANEL MESSAGE SUB-MESSAGE CID CODE DEFINITION
AC POWER 08/00 301 TROUBLE - AC Power
STANDBY BATTERY 09/01 302 TROUBLE - Low System Battery
PANEL TAMPER 11/74/03 137 BURG - Tamper
BACKUP COMM LINE 12/04 352 TROUBLE - Phone Line 2
PANEL GROUND 13/05 310 TROUBLE - Ground Fault
AUXILIARY FUSE 26/27 300 TROUBLE - System Trouble
PHONE LINE 1 28/29 351 TROUBLE - Phone Line 1
PHONE LINE 2 30/31 352 TROUBLE - Phone Line 2
BELL CIRCUIT 38/39 321 TROUBLE - Bell/Siren #1
BELL FUSE 43/53 321 TROUBLE - Bell/Siren #1
SUPERVISED WIRELESS 50/89 381 TROUBLE - RF Sensor Supervised
LONG RANGE RADIO 72/73 353 TROUBLE - Radio Transmitter
DEVICE MISSING 101/102 333 TROUBLE - Exp� Module Fail - ZZZ
CELL COMM BUS FAIL/RST 130/132 333 TROUBLE - Exp� Module Fail - ZZZ
CELL COMM DC POWER 133/134 337 Exp� Module DC Loss
CELL COMM BATTERY 135/135 338 Exp� Module Low Battery
CELL COM TAMPER 137/138/139 341 Exp� Module Tamper
NETWORK TROUBLE 72 356 TROUBLE - Loss of Central Polling
SYSTEM TEST BEGIN/END 66/67 607 TEST - Walk Test Mode