12 Digital Monitoring Products, Inc. | Troubleshooting Guide
4-WIRE BUS TROUBLE
When the keypad displays 4-WIRE BUS TRBL it means that the panel has a problem communicating with the keypad
bus devices� 4-WIRE BUS TRBL is not an indication of LX-Bus issues� More specifically, when the panel polls the keypad
bus devices, they aren’t able to respond�
4-WIRE BUS TRBL only displays for the following reasons:
1
All keypad bus devices set to Unsupervised:
Make sure at least one keypad bus device is set as Supervised�
2
Multiple keypad bus devices set to same Supervised address:
Make sure that all keypad bus devices are addressed correctly (all devices sharing an address*
must be set as UNSUPERVISED)�
3
Low voltage or no voltage on the panel’s Yellow (receive) wire (terminal 8):
Check data voltage (DC) across terminals 8 & 10 at the panel and at the device� If the voltage is low
or open, remove the wires from terminals 7 - 10 and check voltage again�
If still low or open, reset the panel using the J16 jumper and check the voltage again� If voltage is
still low or open, remove all wiring (except AC power) and check again� This last step is taken to
make sure that transient voltage isn’t being fed into the panel from the field wiring�
Note: Multiple UNSUPERVISED devices may share the same address, as long as:
All devices using the same address are set for UNSUPERVISED operation,
None of the devices using the same address are being used for zone expansion, and
There is sucient auxiliary power available to operate the devices� Auxiliary power may be
provided by the panel or an auxiliary power supply or both�
TRANSMIT FAIL
When the keypad displays TRANSMIT FAIL it means that the panel made 10 attempts to communicate with the receiver,
but was unsuccessful�
After the ten attempts have failed, the panel tries once every hour to send a TRANSMIT FAIL message to the receiver
The keypad only displays TRANSMIT FAIL when a user disarms the system or when an unsuccessful SYSTEM TEST has
been initiated from the User Menu�
WHAT TO DO
1
Arm the system� Let the Exit Delay timer count all the way down, and then disarm the system�
If communication to the receiver has been restored (i�e�- the panel successfully communicated the
TRANSMIT FAIL or any other signal), this should clear the display
2
Try to send a test-signal�