EasyManua.ls Logo

Domino F720i

Default Icon
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE AND FAULT FINDING
5-24 EPT031055 Issue 2 September 2017
CHANGING THE FUSES
WARNINGS: (1) Before undertaking any work on the laser
marking system, remove the mains power plug.
(2) This procedure is to be performed by fully
trained engineers only.
(3) Two pole fuses are used.
Main Power Fuses F1 and F2
If a fuse is blown, replace with the same type:
Manufacture: SIBA Sicherungen-Bau GmbH; Lunen, Gemany
(Distributor: Farnell 117-5150) Art.Nr. 70 065 65 – 12.5A T
Rated Current: 12.5A delay
Rated breaking capacity: 1500A / 500V AC
Laser Power Supply Fuse, Label F3
If a fuse is blown replace with the same type
Manufacture: BELfuse (ESKA Type: UL 632.627).
Rated Current 10A fast.
Rated breaking capacity: 200A / 250V AC.