27
2358-065 Issued 7-19
Version E
Program
Step
Factory
Default
Description
Options
Selection
Number
Function
Select desired program steps and PHYSICALLY program EACH tracker expansion board being used with the access control system.
“Basic programming sequence on EACH board” on previous page explains how to program the functions into the board.
Programming Options on EACH Board
Sets Strike Time for output relay (term 25 & 26)
0.25 second strike time
Strike time in 1-second increments
Set Strike Time for RX
(Request to Exit)
of output relay (input at term 18)
0.25 second Egress Strike time
Egress Strike time in 1-second increments
Timer starts when valid access has been granted.
1 second Door Ajar Timer
Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds
Timer setting for Aux Relay activation in 5-second increments
1 second Door Ajar Timer
Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds
Set Strike Time for RX of Aux relay (ONLY available if Dual Door Mode step 12 is ON)
0.25 second Egress Strike time
Egress Strike time in 1-second increments
Set RX (Request to Exit) function. Activate Output Relay or do not Activate Output Relay
Do Not Activate Output Relay or Reader Beeper/LED when RX input is received
Activate Output Relay and Reader Beeper/LED for Free Exit Strike Time when RX
received
Sets type of Door Switch contacts
N.O. contact from door switch with Door Closed (Circuit Open - CO)
N.C. contact from door switch with Door Closed (Circuit Close - CC)
Turns on Auto Relock function (not available if Dual Door Mode, step 12 is ON)
Output Relay is activated for Strike Time
Door Contact Switch required. If door returns to closed position during Strike Time
door will “relock” after 1 second, even if strike time has not expired.
Sets how BEEPER or LED will function during Hold Open
When Hold Open occurs, Beeper or LED is active only during Strike Timer
When Hold Open occurs, Beeper or LED will remain active during Hold Open
Sets how Aux & Alarm Relay responds during Hold Open or Hold Egress situation
No Aux Relay functions. Alarm will be in “Reset”. If Alarm Relay is set for “integral”
mode, Alarm relay will not activate. If Alarm Relay set for “Bypass” mode, Alarm
Relay will activate for Hold Open period or Extended Egress Hold.
Aux Relay will function for all settings. If Alarm Relay is set for “integral” mode,
Alarm relay will not activate. If Alarm Relay set for “Bypass” mode, Alarm Relay will
activate for Hold Open period or Extended Egress Hold.
Sets Tracker to function as 2 Access Points (2 tracker addresses)
Disabled, Tracker functions as single access point
Dual Mode: Tracker functions as set board address and next sequential address
Card Read will be sent to controller as set board address, access is granted or denied
Card then sent as set address +1, access granted or denied. Aux Relay becomes 2nd
output relay. All other Aux Relay functions disabled. Door Contact switch becomes
RX for 2nd address.
Sets function for Aux Relay
Aux Relay Disabled
No Door Ajar Timer: Requires Door Contact Switch. Aux Relay activates when Door
Not Closed.
No Door Ajar Timer, Pulse: Requires Door Contact Switch. Aux Relay “pulses” when
Door Not Closed.
Door Ajar Timer: Requires Door Contact Switch. When door opens, start Door Ajar
Timer. When timer expires Aux Relay activates for Aux Relay timer or until door
closes, whichever occurs first.
Door Ajar Timer, Pulse: Requires Door Contact Switch. When door opens, start
Door Ajar Timer. When timer expires Aux Relay Pulses for Aux Relay timer or until
door closes, whichever occurs first.
Door Ajar, Pulse warning the ON: Requires Door Contact Switch. When door opens,
Pulse Aux Relay and start Door Ajar Timer. When timer expires Aux Relay ON for
Aux Relay timer or until door closes, whichever occurs first.
Door opens for any reason, Start Door Ajar timer and pulse Aux Relay. When Door
Ajar timer expires, start Aux Timer and continue Pulsing Aux Relay. When Door
Closes or both timers expire, turn off Aux Relay.
00
01 - 99
00
01 - 99
00
01 - 99
00
01 - 99
00
01 - 99
0
1
0
1
0
1
0
1
0
1
0
1
0
1
2
3
4
5
6
00 - 99
00 - 99
01 - 99
00 - 99
00 - 99
0 - 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 - 12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Door Strike Timer
Free Exit Timer, Strike Time
Door Ajar Timer
Aux Relay Timer
Free Exit Timer, Aux Relay
Free Exit, No Strike
Not Used
Door Switch Logic
Auto Relock
Beeper / LED Hold Open
Hold Open or Hold Egress
functions
Dual Door Mode
Not Used
Not Used
Aux Relay Functions
01:
1 second
01:
1 second
12:
60 secs
12:
60 secs
01:
1 second
01:
Activate
0:
Disabled
0:
0:
No Relay
Function
0:
Disabled
0:
Disabled
0:
N.O.