4.3 Programming Step Descriptions Continued
Sets the maximum amount of allowable signal strength loss between the wireless tracker expansion board and the wireless baseboard (ONLY
works on WIRELESS tracker expansion board).
Program Step 20: Display RF Range Setting (Wireless ONLY)
Displays current signal loss between the wireless tracker expansion board and the wireless baseboard (ONLY works on WIRELESS tracker
expansion board).
Program Step 21: Display RF Signal Loss (Wireless ONLY)
ONLY USE THIS FEATURE AS DIRECTED BY DOORKING TECH SUPPORT. Sets wireless tracker expansion board to operate as a wireless
repeater and forward card codes (access codes) to the next board in the wireless system when the wireless signal range needs to be extended
(ONLY works on WIRELESS tracker expansion board).
Program Step 22: Card Code Forwarding, Tracker as Repeater (Wireless ONLY)
Sets all parameters to Factory Defaults (See table in section 4.2 for factory default settings).
Program Step 19: Reset to Factory Defaults
Program Step 17: Not Used
Program Step 18: Not Used
Program Step 16: Alarm Relay Functions Continued
Set to 2, Integral Mode Door Ajar Timer. Door contact switch (Input at terminal 15) connected to tracker expansion board (see previous
page for wiring). When door is opened, Door Ajar timer starts (step 3). If door is still open when door ajar timer times out, alarm relay will
activate. Alarm relay will reset when door closes. Door Ajar and Door Close event transactions will be sent from tracker expansion board to
access control system.
Set to 3, Integral Mode Proper and Forced Condition. Door contact switch (Input at terminal 15) connected to tracker expansion board.
Alarm Relay provides connection directly to Alarm System. If door is still open when door ajar timer times out, alarm relay will activate. Alarm
relay will reset when door closes.
If door is opened without Proper condition (see previous page), alarm relay will activate. Alarm Relay deactivates when door closes. Tracker
expansion board sends Door Ajar, Door Close and Door Forced event transactions to access control system.
Set to 4, Gate Alarm Function. Alarm Relay will activate for 1 second when tracker expansion board receives a “Gate Forced” or “Gate
Obstructed” transaction from the gate operator control board (DoorKing gate operators ONLY).