Maintenance Section
-136-
If automatic SCR cleaning is failed, you should carry it out
a while after the vehicle starts working.
A pop-up on the SCR Display warns the operator to
perform SCR Cleaning. (3 warnings: at 10 hrs remaining,
5 hrs remaining, Immediate)
Exemplary warning – 10 hrs remaining
Limit the engine power and stop the current work when
SCR cleaning is not used; you will be violating the exhaust
regulations if you do not.
To carry out SCR cleaning safely, observe the following
steps:
1. Park the vehicle at a safe place. White smoke can be
emitted during SCR Cleaning.
2. Remove the flammable material or stained oil from
exhaust system. High temperature of exhaust system
and gas can cause fire.
3. Engage the parking brake, and make sure the gear is
in neutral.
4. Allow engine to warm up sufficiently; the SCR cleaning
is not possible in cold condition.
5. After holding down the switch at the “3” position for
three seconds, check that SCR cleaning has started.
6. Once SCR cleaning finishes, the LCD display will show
a notification.
Press this switch and release it after 3 sec, SCREEN
Cleaning will be started and the engine speed will be
increased. Screen pop-up provides information on the
warning up and cleaning process.
Warming up process
Proceeding
Completed

Table of Contents