G424F(FE) Service Manual Chapter 9. Advanced Diagnostics 260
Table 1. Fault List Definitions (cont’d.)
FAULT DESCRIPTION
CODE
(MI04 CODE)
TPS2RangeLow
TPS2 sensor voltage out of range low, normally set if TPS2
signal has shorted to ground, circuit has opened or sensor
has failed
222
TPS_Sensors_Conflict
TPS sensors differ by more than expected amount.
NOTE: The TPS is not a serviceable item and can only be
repaired by replacing the DV-EV throttle assembly
291
TransOilTemp Excessive transmission oil temperature 933