Error Code: "Er Fun" Function Error
Cause: This is a normal message that displays when the parameters are
being defaulted by the user - see Section 11.
Error Code: "Er t-" Negative Tare Error (SET mode)
Cause: Attempting to enter a negative tare in the SET mode.
Remedy: Enter only positive tares.
Error Code: "Er tAr" Negative Tare Error (PTT mode)
Cause: Attempting to enter a negative platform weight as a tare.
Remedy: Enter only positive platform weights as tares.
Error Code: "--OL--" Overload
Cause: Weight on scale is over 103% of capacity.
Remedy: Remove excess weight.
Error Code: "--UL--" Underload
Cause: Weight on scale is less than -3% of capacity (platter may be
removed).
Remedy: Replace weighing platter.
Error Code: "grS-OL" Gross Overload
Cause: Weight on platter has greatly exceeded the capacity of the scale,
incorrect connections or calibration, or defective load cell or main
board.
Remedy: Remove excess weight, check connections and calibration, replace
defective load cell or main board.
Error Code: "grS-UL" Gross Underload
Cause: Weighing platter is removed, incorrect connections or calibration, or
defective load cell or main board.
Remedy: Replace platter, check connections and calibration, replace defective
load cell or main board.
Section 10 Error Codes
74