EasyManua.ls Logo

Doran 4200 - Section 13. Technical Specs and Options; Options

Doran 4200
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 13. Technical Specs and Options
OPTIONS
200 PRODUCTS, SETPOINTS, TIME & DATE (TYPE 42 OPT 27)
Option 42 OPT 27 upgrades the number of products to 200 from the standard of 20, and
adds time and date capability. Option 42 OPT 27 also supports setpoint outputs. The
standard 4200 does not support setpoint outputs, so this option must be ordered if
setpoints are going to be used.
REMOTE PUSH-BUTTON
The Model 4200 can support remote push-buttons to emulate the function keys of the touch
panel. These include ZERO, TARE, PRINT, UNITS, and GROSS/NET. The connector for
the push button is on an I/O card that is ordered separately. You will need 2-position Molex
type housings and 2 Molex pins for each remote push-button needed. Contact Doran
Scales, Inc. for proper parts.
INTERNAL BATTERY OPTION
The Internal Battery Option enables the scale to operate on battery power. The battery
charges whenever the AC power cord is plugged in, making it easy to use this option as a
battery back-up. The option can also be used to operate the scale throughout the day on
battery power and recharge the battery overnight by simply plugging in the AC power cord.
A low battery is indicated by flashing a "LOBATT" message on the display periodically.
With the battery option, pressing and holding the ZERO button will turn off the scale at any
time. When holding ZERO, "Rel Pb" will be displayed. Upon release of the zero button, the
scale will turn off.
4200Tower The option includes a 12 VDC, 3.4 Ah lead acid battery, a DC/DC
Converter/Charger card, a special back plate, and hardware. The rated life
of the battery is 20 hours with a single load cell, less with multiple load cells.
The battery requires an 8 hour recharging period (for a fully drained battery).
4200RSS The option includes a 12 VDC, 6.5 Ah lead acid battery, a DC/DC
Converter/Charger card, and hardware. The rated life of the battery is 40
hours with a single load cell, less with multiple load cells. The battery
requires a 16 hour recharging period (for a fully drained battery).
4200M This option is not available for the 4200M - see the External Battery Option
below.
82