10 DORMA
Express-Function
The door can be moved manually in its
driving direction and there will be no extra
resistance. However, when the maximum
speed is exceeded, the driving resistance will
increase in line with the speed by which it is
exceeded. As soon as the user has released
the door panel, the operator will softly slow it
down to maximum speed. This function is
activated during all opening and closing
cycles.
5.6 Safety functions
StaticforcesinLow-Energy-Mode.
The system does not exceed a value of 15 lb
during opening and closing cycles.
Opening cycle
As soon as the door hits an obstacle during
an opening cycle, it will immediately stop and
remain in its position for 3 seconds. Then
the operator will try to continue the opening
cycle. If the door panel hits an obstacle three
time during an opening cycle, it will close.
Closing cycle
When the door panel hits an obstacle while
closing, it will immediately stop and perform
an opening cycle.
5.7
Safety sensors
You can install sensors to detect obstacles.
An automatic sensor test can be activated
or deactivated via the DIP switches located
inside the operator.
The door will stop immediately when the
sensor detects an obstacle during an opening
cycle and will continue the cycle as soon as
the obstacle has been removed. In case the
obstacle is not removed, the door will close on
completion of the adjusted hold-open time.
The door will stop immediately and reverse
when the sensor detects an obstacle during
the closing cycle. This function is not activa-
ted while the door is in closed position (then
the sensor is deactivated).
5.8
Power failure
In the event of a power failure, the door can
be opened and closed by hand.
However, in this case the operator does
not slow down (brake) the door panel, so
that the user has to move (hold) it all the
way by hand.
As soon as the voltage returns, the operator
will automatically perform a position initiali
-
zation.
During this position initialization, it is
essential that the movement range of the
door is free of obstacles.
Installation and Maintenance Manual
CS 80 MAGNEO

Other manuals for Dorma CS 80 MAGNEO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dorma CS 80 MAGNEO and is the answer not in the manual?

Dorma CS 80 MAGNEO Specifications

General IconGeneral
BrandDorma
ModelCS 80 MAGNEO
CategoryDoor Opening System
LanguageEnglish

Related product manuals