32 DORMA
Press and hold the „Reset“ button for more
than 3 seconds.
Do not interrupt the learning cycle as
the system currently learns all values it
requires.
During the learning cycle the door will:
Opentwiceandcloseagain.TheLEDwill
blink green at certain intervals then it will
show a permanent green light.
The CS 80 MAGNEO is now ready for opera-
tion.
How to switch the system from Low-Energy- to
Full-Energy-Mode
Only authorized staff (authorization on
the part of DORMA required) may switch
the CS 80 MAGNEO to Full-Energy-
Mode. As there are higher forces in Full-
Energy-Mode, the closing edges have to
be protected by safety sensors.
Therefore we do not explain how to switch the
system to Full-Energy-Mode in these instruc-
tions.
Only use the enclosed red screwdriver
to perform potentiometer adjustments!
Speed adjustment
The maximum speed depends on
the weight of the door panel. You
can reduce the speed with the aid
of the potentiometer (infinitely
variable).
Adjustment of hold-open time
The door will close automatically
on expiry of the adjusted hold-open
time following it has reached
„open“ position. You can adjust the
hold-open time infinitely from 5 to
30 seconds with the aid of the
potentiometer.
12. Commissioning
Basic requirements
• TheCS80MAGNEOiscompletely
mounted.
• Youcanmovethedoorsmoothlyoverthe
complete movement range.
General information
When you connect the system to the power
supply (plug it in) the green light indicator
blinks and the operator has no function. You
can access the door manually.
In order to make the operator ready for opera
-
tion, you have to perform a learning cycle.
ThegreenLEDgoesonfollowingthelearning
cycle. The CS 80 MAGNEO is now ready for
operation
andoperatesinLow-Energy-Mode.
Apart from during commissioning, a
learning cycle has to be performed every
time the position of an end stop has
been adjusted or the weight of the door
has changed.
This „approach“ describes the commissioning
of the standard door system. Accessories and
different operation modes can be adjusted
after the system has been commissioned.
Sensors are connected and adjusted following
the successful commissioning of the system.
Thelightindicator(LED)willgiveyouvisual
feedback.
The settings stored during the commissioning
of the system can be overwritten by perfor-
ming a new commissioning.
Learning cycle
In order to start the learning cycle:
• Thedoormustbeopen.
• Theoperatormustbeswitchedon.
• Themovementrangeofthedoormustbe
free of obstacles.
The
greenLEDwillblinkbeforethefirst
learning cycle.
speed /
Geschwindigkeit
hold open time /
Offenhaltezeit
Installation and Maintenance Manual
CS 80 MAGNEO

Other manuals for Dorma CS 80 MAGNEO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dorma CS 80 MAGNEO and is the answer not in the manual?

Dorma CS 80 MAGNEO Specifications

General IconGeneral
BrandDorma
ModelCS 80 MAGNEO
CategoryDoor Opening System
LanguageEnglish

Related product manuals