EasyManua.ls Logo

Dover OPW SiteSentinel Integra 100 - Flex Probe Installation; Model 7100 V Flex Probe; Model 7100 V Flex Probe Specifications

Dover OPW SiteSentinel Integra 100
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Doc. #: M1800, Rev. 06
Page 46 of 101
www.opwglobal.com
10 Flex Probe Installation
10.1 Model 7100V Flex Probe (only for Integra
500)
The 7100V Flex Probe utilizes the same magnetostrictive technology
for above ground tanks up to 70 feet (15.2 m) in height. It is important
to follow the handling instructions to avoid damaging the probe and
voiding the warranty. During the unpacking and installation of the
Model 7100V Flex Probe, always keep the diameter of the coils
between 40 and 48 inches (about 1 m).
Flex Probe Installation Requirement: Flex probe head/wiring must
be installed in weatherproof junction box with seal packs for wiring
connections. Failure to comply with these requirements may
invalidate probe warranty.
10.2 Model 7100V Flex Probe Specifications
DO NOT
REMOVE
YELLOW
TAG
Figure 10-1 Model 7100V Flex Probe

Table of Contents

Related product manuals