5 Programming Worksheets
21
[170] PGM Output Timer
Default 005 I_______I_______I_______I Valid entries are 001-255 seconds
[175] Auto-arm Postpone Timer
Default 000 I_______I_______I_______I Valid entries are 000-255 seconds, 000 to disable
Attribute: 9 10 11 12 13 14 15 16
=ON
Cross
Zn
Zone Attributes 10-13 for
Future Use
NC
Loops
SEOL DEOL
Zone Type: OFF No Config. Config. Config.
00 Null Zone
01 Delay 1
02 Delay 2
03 Instant
04 Interior
05 Interior Stay/Away
06 Delay Stay/Away
07 Delay 24-hr. Fire (Hardwired)
08 Stand 24-hr. Fire (Hardwired)
09 24-hr. Supervisory (Hardwired)
10 24-hr. Supervisory Buzzer
11 24-hr. Burglary
12 Not Used
13 24-hr. Gas
14 24-hr. Heat
15 24-hr. Medical
16 24-hr. Panic
17 24-hr. Emergency
18 Not Used
19 24-hr. Water
20 24-hr. Freeze
21 24-hr. Latching Tamper
22 Momentary Keyswitch Arm
23 Maintained Keyswitch (Hardwired)
24 Not Used
25 Interior Delay
26 24-hr. Non-Alarm
27–30 Not Used
31 Day Zone
32 Instant Stay/Away
33-34 Not Used
35 24-hr. Bell/Buzzer Zone Type
36 24-hr. Non-Latching Tamper
37 Night Zone
41 24-hr. Carbon Monoxide Detection
[168] Daylight Saving Time Begins [169] Daylight Saving Time Ends
Default EU
Default
Valid entries
Default EU
Default
Valid entries
003 003 Month
|_______|_______|_______|
001-012 011 010 Month
|_______|_______|_______|
001-012
002 005 Week
|_______|_______|_______|
000-005 001 005 Week
|_______|_______|_______|
000-005
000 000 Day
|_______|_______|_______|
000-031 000 000 Day
|_______|_______|_______|
000-031
002 001 Hour
|_______|_______|_______|
000-023 002 001 Hour
|_______|_______|_______|
000-023
001 001 Increment
|_______|_______|_______|
001-002 001 001 Decrement
|_______|_______|_______|
001-002