EasyManua.ls Logo

DSC PowerSeries PC1404 - Closing (Arming) Reporting Codes; Opening (Disarming) Reporting Codes; Automatic Clock Adjust; First International Options

DSC PowerSeries PC1404
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Programming Worksheets
29
[601] Closing (Arming) Reporting Codes, Access Codes 33-40
[605] Opening (Disarming) Reporting Codes, Access Codes 33-40
INTERNATIONAL PROGRAMMING
[700] Automatic Clock Adjustment
Default = 60 |______|_______| Valid Entries 00-99 Seconds
[701] First International Options
Note: Programming options indicated in grey are EU defaults.
[702] Second International Options
[703] Delay Between Dialing Attempts
Default = 003 |_______|_______|_______| V alid entries are 000-255 seconds (entry + 5 seconds)
[900] Panel Version
[901] Installer Walk Test Mode Enable/Disable
See [901] Installer Walk Test Mode Enable/Disable.
[902] Module Supervision Reset
See [902] Module Supervision Reset.
[903] View Module Supervision
See [903] View Module Supervision.
[990] Installer Lockout Enable
[991] Installer Lockout Disable
[999] Restore Panel Factory Defaults
PC5204
[561] PGM 11
[562] PGM 12
[563] PGM 13
[564] PGM 14
Code 33 Code 34 Code 35 Code 36 Code 37 Code 38 Code 39 Code 40
|___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___|
Code 33 Code 34 Code 35 Code 36 Code 37 Code 38 Code 39 Code 40
|___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___|
Opt Def. ON OFF
1
50 Hz AC

60 Hz AC
2
Time Base - Internal Crystal

Time Base - AC Line
3
AC/DC Arming Inhibit Enabled

AC/DC Arming Inhibit Disabled
4
All System Tampers Require Installer Reset

All System Tampers Follow Restore
5
6-digit User Access Codes

4-digit User Access Codes
6
Busy Tone Detection Enabled

Busy Tone Detection Disabled
7-8
For Future Use

Opt Def. ON OFF
1
Pulse Dialing Make/Break Ratio is 33/67

Pulse Dialing Make/Break Ratio is 40/60
2

Force Dialing Enabled
Force Dialing Disabled
3
For Future Use

4
1600Hz Handshake

Standard Handshake
5
ID Tone Enabled

ID Tone Disabled
6
2100 Hz ID Tone

1300 Hz ID Tone
7
For Future Use

8
For Future Use

_BB0BB_BB1BB_BB0BBB_BB0BB_
Not Programmable
Enter [990] [Installer's Code] [990]
Enter [991] [Installer’s Code] [991]
Enter [999] [Installer’s Code] [999]
Section Number Output Number Zone Follower Zone

Table of Contents

Other manuals for DSC PowerSeries PC1404

Related product manuals