5 Programming Worksheets
29
[601] Closing (Arming) Reporting Codes, Access Codes 33-40
[605] Opening (Disarming) Reporting Codes, Access Codes 33-40
INTERNATIONAL PROGRAMMING
[700] Automatic Clock Adjustment
Default = 60 |______|_______| Valid Entries 00-99 Seconds
[701] First International Options
Note: Programming options indicated in grey are EU defaults.
[702] Second International Options
[703] Delay Between Dialing Attempts
Default = 003 |_______|_______|_______| V alid entries are 000-255 seconds (entry + 5 seconds)
[900] Panel Version
[901] Installer Walk Test Mode Enable/Disable
See [901] Installer Walk Test Mode Enable/Disable.
[902] Module Supervision Reset
See [902] Module Supervision Reset.
[903] View Module Supervision
See [903] View Module Supervision.
[990] Installer Lockout Enable
[991] Installer Lockout Disable
[999] Restore Panel Factory Defaults
PC5204
[561] PGM 11
[562] PGM 12
[563] PGM 13
[564] PGM 14
Code 33 Code 34 Code 35 Code 36 Code 37 Code 38 Code 39 Code 40
|___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___|
Code 33 Code 34 Code 35 Code 36 Code 37 Code 38 Code 39 Code 40
|___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___| |___|___|
Opt Def. ON OFF
1
50 Hz AC

60 Hz AC
2
Time Base - Internal Crystal

Time Base - AC Line
3
AC/DC Arming Inhibit Enabled

AC/DC Arming Inhibit Disabled
4
All System Tampers Require Installer Reset

All System Tampers Follow Restore
5
6-digit User Access Codes

4-digit User Access Codes
6
Busy Tone Detection Enabled

Busy Tone Detection Disabled
7-8
For Future Use

Opt Def. ON OFF
1
Pulse Dialing Make/Break Ratio is 33/67

Pulse Dialing Make/Break Ratio is 40/60
2

Force Dialing Enabled
Force Dialing Disabled
3
For Future Use

4
1600Hz Handshake

Standard Handshake
5
ID Tone Enabled

ID Tone Disabled
6
2100 Hz ID Tone

1300 Hz ID Tone
7
For Future Use

8
For Future Use

_BB0BB_BB1BB_BB0BBB_BB0BB_
Not Programmable
Enter [990] [Installer's Code] [990]
Enter [991] [Installer’s Code] [991]
Enter [999] [Installer’s Code] [999]
Section Number Output Number Zone Follower Zone

Table of Contents

Other manuals for DSC PowerSeries PC1404

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC1404 and is the answer not in the manual?

DSC PowerSeries PC1404 Specifications

General IconGeneral
BrandDSC
ModelPowerSeries PC1404
CategorySecurity System
LanguageEnglish

Related product manuals