5 Programming Worksheets
25
[367] Opening/Closing Communicator Call Directions
[375] System Maintenance Alarm/Restore Communicator Call Directions
[376] System Test Transmissions/Communicator Call Directions
[377] Communication Variables
[378] Test Transmission Time of Day
Default
[380] First Communicator Options
[381] Second Communicator Options
Option 1
First Telephone
Number (Default OFF)
Option 2
Second Telephone
Number (Default OFF)
Option 3
Third Telephone
Number (Default OFF)
Option 4
Fourth Telephone
Number (Default OFF)
Option 5-8
Future Use
(Default OFF)

Option 1
First Telephone
Number (Default ON)
Option 2
Second Telephone
Number (Default OFF)
Option 3
Third Telephone
Number (Default OFF)
Option 4
Fourth Telephone
Number (Default OFF)
Option 5-8
Future Use
(Default ON)

Option 1
First Telephone
Number (Default ON)
Option 2
Second Telephone
Number (Default OFF)
Option 3
Third Telephone
Number (Default OFF
Option 4
Fourth Telephone
Number (Default OFF)
Option 5-8
Future Use
(Default OFF)

Default EU
Default
003
I_______I______I_______I
Swinger Shutdown (Alarms and Rest) 001-014 Transmissions, 000=disabled
003
I_______I______I_______I
Swinger Shutdown (Tampers and Rest) 001-014 Transmissions, 000=disabled
003
I_______I______I_______I
Swinger Shutdown (Maint. and Rest) 001-014 Transmissions, 000=disabled
000
I_______I______I_______I
Communication Delay 000-255 seconds
030
I_______I______I_______I
AC Failure Communication Delay 000-255 minutes/hours
010 002
I_______I______I_______I
TLM Trouble Delay (# of valid checks required 10 x 3s)
030
I_______I______I_______I
Test Transmission Cycle (land line) 001-255 hours/days, 000=disabled
007
I_______I______I_______I
Future Use Future Use
030
I_______I______I_______I
Delinquency Transmission Delay 001-255 days/hours, 000=disabled
000
I_______I______I_______I
Communications Cancelled Window 005-255 minutes (CP-01 Only)
9999
I_______I_______I_______I_______I (Valid entries are 0000-2359, 9999 to disable)
Opt Def. ON OFF
1

Communications Enabled
Communications Disabled
2
Restores on Bell Time-out

Restores Follow Zones
3
Pulse Dialing

DTMF Dialing
4
Switch to Pulse Dialing after 4 Attempts

DTMF Dial for all Attempts
5
For Future Use

6
Alternating Backup Dialing Enabled
Call Primary Number, Backup to Secondary
7
For Future Use

8
Delinquency Follows Zone Activity (Hours)

Delinquency Follows Arming (Days)
Opt.
Def.
ON OFF
1
Opening After Alarm Keypad Ringback Enabled

Opening After Alarm Ringback Disabled
2
For Future Use


Table of Contents

Other manuals for DSC PowerSeries PC1404

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC1404 and is the answer not in the manual?

DSC PowerSeries PC1404 Specifications

General IconGeneral
BrandDSC
ModelPowerSeries PC1404
CategorySecurity System
LanguageEnglish

Related product manuals