5.3 Programming Descriptions

[551-564] Extended PGM Attributes for PGM Type 29, Zone Follower [551]-[564]
The following attributes are available for the Zone Follower PGM Option [29]:
[601] Closing by Master Code
When the system is armed, a closing reporting code is transmitted after the exit delay expires for the master code that armed the system.
This reporting code is sent to the Opening & Closing call direction group of the system. In addition, either “Armed in Stay Mode” or
“Armed in Away Mode” is logged to the event buffer.
[605] Opening by Master Code
When the system is disarmed, an opening Reporting code for the Master code is transmitted. These reporting codes are sent to the
Opening and Closing call direction group.
The following attributes are available for the System Trouble PGM Option [09].
System Trouble PGM (Type 09)
[1] Service Required
[2] A.C. Failure
[3] Telephone Line Fault
[4] Communications (Failure to Communicate)
[5] Device (Fire) Fault / WLS Zone Supervisory Fault Enabled
[6] Device Tamper—hardwired or wireless device
[7] Device Low Battery—wireless device
[8] Loss of Clock
The following attributes are available for the System Event PGM Option [10]
System Event PGM (Type 10)
[1] Burglary Delay, Instant, Interior, Stay/Away, Night, and 24 Hour Burglary Zone Types
[2] Fire Key, Fire zone
[3] Panic Key and Panic zones
[4] Medical Key, Medical, and Emergency zones
[5] Supervisory Supervisory, Freeze, and Water zones
[6] Priority Gas, Sprinkler, CO, 24-Hour Heat and 24-Hour non-Latching Tamper zones
[7] Hold-up Duress alarms
[8] Output Options ON: Output Follows PGM Timer (Attribute 8). The output activates for the duration pro-
grammed for the PGM output timer (Section [170]).
OFF: Output is latched. The output is active until a valid access code is entered.
i
If a system event PGM is programmed to follow the command output timer (Attribute 8 On), all other PGM attributes must
be enabled.
[1]-[2] Future Use ON: Output energizes when activated
[3] Output level OFF: Output de-energizes when activated
[4]-[7] Future Use ON: AND Logic
[8] Priority OFF: OR Logic
The following attributes are programmable in Installer Sections [551-[564]. Depending on which PGM is used for zone follower
(Onboard, PC5208 or PC5204), the attributes need to be changed in the appropriate section.
Zone 1 ON: Zone 1 Enabled for Zone Follower
OFF: Zone 1 Disabled for Zone Follower
Zone 2 ON: Zone 2 Enabled for Zone Follower
OFF: Zone 2 Disabled for Zone Follower
Zone 3 ON: Zone 3 Enabled for Zone Follower
OFF: Zone 3 Disabled for Zone Follower
Zone 4 ON: Zone 4 Enabled for Zone Follower
OFF: Zone 4 Disabled for Zone Follower
Zone 5 ON: Zone 5 Enabled for Zone Follower
OFF: Zone 5 Disabled for Zone Follower
Zone 6 ON: Zone 6 Enabled for Zone Follower
OFF: Zone 6 Disabled for Zone Follower
Zone 7 ON: Zone 7 Enabled for Zone Follower
OFF: Zone 7 Disabled for Zone Follower
Zone 8 ON: Zone 8 Enabled for Zone Follower
OFF: Zone 8 Disabled for Zone Follower

Table of Contents

Other manuals for DSC PowerSeries PC1404

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC1404 and is the answer not in the manual?

DSC PowerSeries PC1404 Specifications

General IconGeneral
BrandDSC
ModelPowerSeries PC1404
CategorySecurity System
LanguageEnglish

Related product manuals