TESTING THE SYSTEM
56 D-306232 WP8010/WP8030 V18 DSC EN USER
Periodic Test per Partition
In addition to the regular Periodic Test, you can also test zones for enrolled sensors (excluding temperature
sensors and sirens) that are assigned to a selected partition.
A. To Conduct the Periodic Test per Partition
1
1.
P1:R P2:N P3:-
Make sure the selected partition is disarmed and the other partitions are not
in exit or entry delay and then press the partition ( ) button.
MEMORY
TROUBLE
2.
SELECT PARTITION
When the display reads [SELECT PARTITION], press the partition number of
the zones you wish to test, for example, (Partition 1).
3.
Partition 1
4.
Press the button repeatedly until the display reads [PERIODIC TEST]
and press .
PERIODIC TEST
5.
ENTER CODE:
The screen will now prompt you to enter your Master user code.
6.
CODE
Enter your Master user code.
2
P1 SENSORS TEST
3
7.
To enter the devices test procedure per partition, press .
8.
NOT ACTIVE NNN
The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled
devices in the panel that have not been tested yet. This number automatically
drops one count for every tested device.
Test per partition is performed by activating each device as explained in point
4 in the Additional Information table below.
After a device has been activated, the control panel reads [Zxx IS ACTIVATED]
and the "N" indicator drops one count.
After all devices have been tested, the control panel reads [DEVICE TESTS END].
DEVICE TESTS END
9.
Press .
5
Return to step 3
Additional Information (Periodic Test per Partition)
1
Partitioning must be enabled by your installer.
2
If you have not already changed your personal code number, use the default setting 1111.
3
To abort, press the button; the display reads [<OK> TO END]. Press the button.
4
To activate system devices during the "Periodic Test Per Partition"; make sure the device LED lights when
activated:
Contact sensor:
Open or close the door or window protected by the contact.
Motion sensors:
Perform a "walk test" of the detector as explained in the detector's datasheet.
Smoke sensors:
Perform a "Diagnostic test" as explained in the detector's datasheet.
5
Periodic test per partition will be interrupted (the panel returns to selected partition display) upon occurrence of
one of the following: 1) Disarm event by keyfob, keypad or pendant assigned to a selected partition; 2) PANIC,
FIRE or EMERGENCY event.

Table of Contents

Other manuals for DSC WP8030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC WP8030 and is the answer not in the manual?

DSC WP8030 Specifications

General IconGeneral
BrandDSC
ModelWP8030
CategoryControl Panel
LanguageEnglish

Related product manuals