EasyManuals Logo

DSC WP8030 User Manual

DSC WP8030
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
APPENDICES
64 D-306232 WP8010/WP8030 V18 DSC EN USER
Table A1 Common Area Definitions
Common area zone types
Definition
Perimeter
Acts as defined only after the last assigned partition is armed AWAY or
HOME.
In case that one of the partitions is disarmed, an alarm initiated from this zone
is ignored for all assigned partitions.
Delay zones
Delay zones will not trigger an entry delay unless all assigned partitions are
armed. It is, therefore, not recommended to define delay zones as common
areas.
Perimeter follower
Act as defined only after the last assigned partition is armed AWAY or HOME.
In case that one of the partitions is disarmed, an alarm initiated from this zone
is ignored for all assigned partitions.
In case that one of the common area assigned partitions is in a delay state
(and the other partitions are armed), the alarm will behave as a perimeter
follower for this partition only. The event will be ignored for other assigned
armed partitions.
Interior
Acts as defined only after the last assigned partition is armed AWAY.
In case that one of the partitions is disarmed or armed HOME, an alarm
initiated from this zone is ignored for all assigned partitions.
Interior follower
Acts as defined only after the last assigned partition is armed AWAY.
In case that one of the partitions is disarmed or armed HOME, an alarm
initiated from this zone is ignored for all assigned partitions.
In case that one of the common area assigned partitions is in a delay state
(and the other partitions are armed), the alarm will behave as an interior
follower for this partition only. The event will be ignored for other assigned
armed partitions.
Home / Delay
Acts as a Perimeter-Follower type when all assigned partitions are armed
AWAY.
Acts as a Delay type when at least one of the assigned partitions is armed
HOME.
Will be ignored when at least one of the assigned partitions is disarmed.
Emergency; Fire; Flood;
Gas; Temperature; 24-hour
silent; 24-hour audible;
Non-alarm
Always armed.

Table of Contents

Other manuals for DSC WP8030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC WP8030 and is the answer not in the manual?

DSC WP8030 Specifications

General IconGeneral
BrandDSC
ModelWP8030
CategoryControl Panel
LanguageEnglish

Related product manuals