EasyManua.ls Logo

DXV AT200 - Troubleshooting - Cleansing and Heating; Cleansing Function Problems; Seat Heating and Dryer Issues

DXV AT200
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5656
IntermittentFlushingMethod
Water in the seat unit is drained every 3 minutes to prevent
water in the seat unit from freezing. The toilet is flushed
every 6 minutes to prevent water in the toilet from freezing.
1
PresstheMassage[C]andNozzleCleaning
[D]buttonssimultaneouslyfor2seconds.
* Water is drained from the seat unit every 3
minutes for approximately 1 minute to prevent
water from freezing while the toilet is not used.
* The toilet is flushed every 6 minutes.
* Water is not drained when the seat is occupied.
*
Once the cleansing is stopped, the cleansing mode
starts with rear cleansing when SHOWER is pressed.
Preventing Freezing
To cancel the intermittent flushing
PresstheMassageandAutoCleanbuttonssimultaneouslyfor2seconds.
* A beep sounds when the setting is canceled.
To prevent remaining water in the seat unit from freezing, drain water according to the procedure given below.
DrainingtheSeatUnit
1 Closethewatershutoffvalvetostop
watersupply.
2 Press the Flush/Full button or the flush
buttonontheseatunit.
* Wait for about 20 seconds before performing
the next procedure.
3 Remove the side cover on the left side of
theseatunit.(Page51)
4
Place a piece of cloth under the filter on
the left side of the seat unit and remove
thefiltertodraintheseatunit.
[Note]
• Becarefulnottodamagethewatersupplyhose
whenremovingthelter.
止水栓開.eps
1
2
2
1
[C]
[D]