6.3.5 Set the AC/LOOP Timer
The AC/LOOP timer activates a countdown timer for use with a motion detector or floor loop. The
AC/LOOP timer is also used when the reversing edge is triggered
• Press and release AC/LOOP close timer button. AC Delay_Timer=## displays on the LCD.
AC/LOOP
Timer
M-00098
06/13/05
JOG
UP/RESET
JOG
DOWN
CLOSE
OPEN
MC/PB
MENU
ENTER
CLOSE
TIMERS
AC/LOOP
PROGRAM
RUN
TIMERS
MESSAGE DISPLAY COUNTER
MESSAGE DISPLAY COUNTER
AC Delay
Time=##
Figure 6-21: AC/LOOP Close Timer
Note: If the value is set to zero, the door will come down after it reaches the open limit.
• Press and release the PROGRAM buttons to change the countdown time to the desired
duration. See Figure 6-22.
Increase
Setting
M-00096
06/09/05
JOG
UP/RESET
JOG
DOWN
CLOSE
OPEN
MC/PB
MENU
ENTER
CLOSE
TIMERS
AC/LOOP
PROGRAM
RUN
TIMERS
Decrease
Setting
Figure 6-22: Change Setting
• The DYNALOGIX II automatically saves the changes.