9.1 Setting the closing limit switch
When 5 LEDs are blinking, give the “step
by step” command. The leaf [2] must
move first to complete the closing
sequence. It must stop when it reaches
the mechanical limiter, and the right LED
will turn red. Issue the second “step by
step” command. Leaf [1] should close.
When it reaches the mechanical limiter, it
should stop, and the left LED will turn red.
9.2 Setting the opening and delay limit switch
Issue the “step by step” command. Leaf [1] will start to
open. When it reaches the point where leaf [2] should
start opening, give another “step by step” command.
The two halves of the gate will now open until they
reach their respective mechanical limiters. The two red
LEDs on the left and right will be turned on.