4 Eaton 9355 UPS (10/15 kVA) User’s Guide 164201594—Rev H0
(PXGMS) connectivity card in an X-Slot communication bay and an Environmental Monitoring Probe (EMP) for
battery temperature/humidity monitoring. See Chapter 6 Communication, for additional information.
11..33 BBaatttteerryy SSyysstteemm
The battery system provides emergency short-term backup power to safeguard operation during brownouts,
blackouts, and other power interruptions.
11..33..11 BBaatttteerryy CCoonnffiigguurraattiioonnss
The 9355 UPS battery system can be internal to the UPS cabinet, an Extended Battery Module/s (EBM)s, or a
combination of both. The EBMs are connected in parallel with the internal batteries to provide extended run
time. The battery system is equipped with sealed lead-acid, maintenance-free batteries.
An external battery disconnect switch or tie point must be used when battery systems are located separate
from the UPS cabinet and wiring exceeds the number of battery terminals available.
A supplemental 48 Vdc shunt trip signal for the battery disconnect device is provided by the UPS, but is not
required for normal operation.
11..44 UUssiinngg TThhiiss MMaannuuaall
This manual describes how to install and operate the Eaton 9355 UPS. Read and understand the procedures
described in this manual to ensure trouble-free installation and operation. In particular, be thoroughly familiar
with the REPO procedure or the LOAD OFF procedure, see Chapter 7 UPS Operating Instructions.
The information in this manual is divided into sections and chapters. The system, options, and accessories
being installed dictate which parts of this manual should be read. At a minimum, Chapter 1 Introduction
through Chapter 4 UPS System Installation and Chapter 7 UPS Operating Instructions should be
examined.
Read through each procedure before beginning the work. Perform only those procedures that apply to the UPS
system being installed or operated.
11..55 CCoonnvveennttiioonnss UUsseedd iinn TThhiiss MMaannuuaall
This manual uses these type conventions:
Bold type highlights important concepts in discussions, key terms in procedures, and menu options, or
represents a command or option that you type or enter at a prompt.
Italic type highlights notes and new terms where they are defined.
Screen type represents information that appears on the screen or LCD.
Icon
Description
Note Information notes call attention to important features or instructions.
[Keys] Brackets are used when referring to a specific key, such as [Enter] or [Ctrl].
In this manual, the term UPS refers only to the UPS cabinet and its internal elements. The term UPS system
refers to the entire power protection system the UPS cabinet, an external battery system, and options or
accessories installed.
The term line-up-and-match refers to accessory cabinets that are physically located adjacent to the UPS. The
term standalone refers to accessory cabinets that are located separate from the UPS.
Left and right side notations are referenced standing in front of the cabinet.
Introduction