M-Max Series adjustable frequency drive
46 For more information visit: www.eaton.com
MN04020002E
February 2010
Table 11: All Parameters (continued)
PNU ID
Access
Right
RUN Designation Value Range
Factory
Setting
User
Setting
User Set
S4.1 830 Display contrast 0 – 15 7
S4.2 831 Factory setting
(WE)
0 = Retain current values
1 = Clears all values and restores
default settings
0
S4.3 832 Password 0
Display Values
M1.1 1 Output
frequency
Hz 0.00
M1.2 25 Frequency
reference value
Hz 0.00
M1.3 2 Motor shaft
speed
rpm (calculated value, rpm) 0
M1.4 3 Motor current A 0.00
M1.5 4 Motor torque % (calculated value) 0.0
M1.6 5 Motor power % (calculated value) 0.0
M1.7 6 Motor voltage V 0.0
M1.8 7 Intermediate DC
bus voltage
V 0.0
M1.9 8 Unit temperature ˚C 0
M1.11 13 Analog input 1 % 0.0
M1.12 14 Analog input 2 % 0.0
M1.13 26 Analog output 1 % 0.0
M1.14 15 Digital input 1 – 3 DI1, DI2, DI3 status 0
M1.15 16 Digital input 4 – 6 DI4, DI5, DI6 status 0
M1.16 17 Digital output RO1, RO2, DO status 1
M1.17 20 PID reference
value
% 0.0
M1.18 21 PID feedback % 0.0
M1.19 22 PID error value % 0.0
M1.20 23 PID output % 0.0
M1.21 1479 Pulse counter
value
0.0
Parameters marked with "M" (Monitor) are values currently being measured, variables
calculated from these measured values, or status values from control signals.
They cannot be edited.