4-14
Data + RSSI;
Data + short address + RSSI;
Data + long address + RSSI;
Module output power: high power consumption
requirements, where the distance is not required,
the transmission power can be reduced to save
average power consumption;
A8 8A;It is used to determine whether the data received
by the air in the air is a remote configuration command.
Customers can change the unlimited configuration ID
according to the requirements. The default is A8 8A;
Used to configure the group number of the device in
network;
Group number corresponding to the target when
configuring device multicast;
Wake-up
period
(sleep time)
It is used to configure the wake-up period of the
end-device sleep device. The larger the period is, the
lower the overall power consumption is, but the greater
the delay of receiving data is;
Lost parent
node
reconnectio
n period
When the parent node is lost (the coordinator is powered
down), the end-device reconnects the previous network
at regular intervals;
Maximum
times of
reconnectio
ns
After the parent node is lost, the maximum times of
reconnections, if it has not been reconnected
successfully, clears the previous network information,
rescans the new network, and the scanning period is
equal to the reconnection period;
Access/control module level status of the GPIO channel;
Access/control module duty cycle and period of the
PWM channel;
Read the ADC value of the device, where 0 channel can
read the device power voltage value;