EasyManua.ls Logo

Ebyte E180-Z6907A - Network Operation Instruction Set

Ebyte E180-Z6907A
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chengdu Ebyte Electronic Technology Co.,Ltd E180-Z6907A User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd.
4-19
configuration ID
Return
:
FA 31
Return
:
FA 31
Configure all network parameters
Send:FD 1A FE all_info FF
Return:FA FE
Send:FD 1A FE 03 FE 5B
01 0B 0A 09 54 00 00 00 0A
1C 21 FE FF 57 B4 14 02 00
FF 05 05 A8 8A FF
Return:FA FE
Configure Remote/Local GPIO
Input and Output Status
Command:FD 03 20 GpioId In/Out
level FF
Return:FA 20
Send:FD 03 20 00 01 01 FF
Return:FA 20
Configure remote/local PWM
status
Command:FD 06 21 PwmId
start/stop
Period1 Period2 duty1
duty2 FF
Return:FA 21
Send:FD 06 21 00 FF 03 65
02 48 FF
Return:FA 21
Device restart
Send:FD 00 12 FF
Return:FA 12
Send:FD 00 12 FF
Return:FA 12
Restore factory settings
Send
:
FD 00 13 FF
Return
:
FA 13
Send
:
FD 00 13 FF
Return
:
FA 13
Read the delayed
printing time of AUX
wake up external MCU
serial port in wireless
receiving state
Send:FD 01 35 AUX_delaytime FF
Return:FA 35
Send:FD 01 35 04 FF
Return:FA 35
Read UART wake up
keep time
Send:FD 01 36 Uart_holdtime FF
Return:FA 36
Send:FD 01 36 64 FF
Return:FA 36
Read port info.
Send:FD 05 37 Endpoint_info FF
Return:FA 37
Send:FD 05 37 01 FE B0
05 04 FF
Return:FA 37
Read link key of trust
center
Send:FD 10 38 TrustCentLinkKey FF
Return:FA 38
Send:FD 10 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
FF
Return:FA 38
6.5.4 Network operation instruction set
Open network
Send:F5 01 40 01 FF
Return:FC 40 00
Send:F5 01 40 01 FF
Return:FC 40 00
Leave Network
Send
:
F5 01 40 02 FF
Return
:
FC 40 00
Send
:
F5 01 40 02 FF
Return
:
FC 40 00
Create network
Send
:
F5 01 40 03 FF
Send
:
F5 01 40 03 FF

Table of Contents