Section 8. Engines & Fire Protection Eclipse 5OO Systems Manual
Copyright © — Eclipse Aviation Corporation
178 Version 2.0 April 2007
8.8 Crew Alerting System Messages
Table 20. Engine CAS Messages
Message Condition Category
L (R) ENG FAIL Left or Right Engine failure Warning
L (R) ENG FIRE Engine fire detected Warning
L (R) ENG EXCEEDANCE
Engine has exceeded limits (N1, N2, ITT,
expiration of 5 minute T/O thrust or 10 minute APR
ON timer.)
Warning
L (R) ENG OIL TEMP HIGH Oil temperature exceeds allowable limits Warning
L (R) ENG OIL PRESS HIGH Oil pressure exceeds allowable limits Warning
L (R) ENG OIL PRESS LOW Oil pressure below allowable limit Warning
L (R) ENG FUEL HOT
Fuel temperature at engine Fuel Metering Unit
(FMU) exceeds limits
Warning
ENG START ABORT Engine start aborted by FADEC (ground only) Caution
L (R) ENG CONTROL FAIL
A failure has occurred in the engine control system
that may degrade engine control. The engine may
fail to a fixed fuel flow or throttle setting
Caution
L (R) ENG OIL TEMP HIGH Oil temperature is between 135°C and 140°C Caution
L (R) ENG OIL TEMP LOW Oil temperature below 20°C (ground only) Caution
L (R) ENG CHIP DETECTED Metal particles detected in engine oil (ground only) Advisory
L (R) ENG CHIP FAULT
Engine oil chip detector has failed and may not be
ale to detect metal in the engine oil (ground only)
Advisory
L (R) ENG CONTROL
A loss of redundancy in the engine control system
has occurred. Engine operation is not affected.
(ground only)
Advisory
L (R) ENG OIL BYPASS
FAULT
The engine oil filter bypass pressure switch failure
(ground only)
Advisory
L (R) ENG OIL FILTER
The engine oil filter pressure switch has tripped,
the oil filter may be bypassed (ground only)
Advisory
L (R) ENG OIL TEMP FAULT
Engine oil temperature sensor failure. (ground
only)
Advisory
ENG START FAIL
Aircraft systems did not automatically configure for
start
Advisory
L (R) EXTNGR DSCHG
Left or right fire extinguisher has discharged.
Once discharged, the fire extinguisher capability
has been depleted
Advisory
L (R) FIRE DETECTOR
FAULT
Fire detection circuit is shorted or open. Fire
detection is unavailable.
Advisory
APR DISARMED APR disarmed (ground only) Status