System Management Commands
4-61
4
show system
This command displays system information.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Command Usage
For a description of the items shown by this command, refer to “Displaying
System Information” on page 3-11.
The POST results should all display “PASS.” If any POST test indicates
“FAIL,” contact your distributor for assistance.
Example
Console#show system
System description: 8 SFP ports + 4 Gigabit Combo ports L2/L3/L4 managed
standalone switch
System OID string: 1.3.6.1.4.1.259.6.10.57
System information
System Up time: 0 days, 1 hours, 23 minutes, and 44.61 seconds
System Name : [NONE]
System Location : [NONE]
System Contact : [NONE]
MAC address : 00-30-f1-47-58-3a
Web server : enable
Web server port : 80
Web secure server : enable
Web secure server port : 443
Telnet server : enable
Telnet port : 23
Jumbo Frame : Disabled
POST result
DUMMY Test 1.................PASS
UART LOOP BACK Test..........PASS
DRAM Test....................PASS
Timer Test...................PASS
PCI Device 1 Test............PASS
Switch Int Loopback test.....PASS
Done All Pass.Port 12 link-up notification.
Console#