54Service Guide: EFI Fiery Central integrated server
Replacing parts
To reassemble the FC integrated server and verify functionality
1 Reseat all boards, cables, connectors, and other parts loosened or removed during service.
When routing cables inside the FC integrated server, make sure that:
Covers are securely installed after routing cables
Cable routing does not interfere with the operation of internal components nor interfere with removing or
replacing components
Cables are not tangled nor looped around internal circuit boards or components (such as capacitors and
resistors)
Cables do not lie on or against any internal heating element
Cables do not interfere with opening or closing FC integrated server panels
Cable slack is secured with a tie-wrap
2 Restore the FC integrated server to the upright position.
3 Replace any panels that you removed earlier, as described on page 18.
4 If you replaced the motherboard, make sure that the new motherboard solves the problem that you are
troubleshooting (see page 28).
5 If the FC integrated server is to be mounted on the furniture with the monitor, see the reassembly instructions on
page 82.
6 Connect the power cable to the FC integrated server.
7 Connect to the network.
8 Ask the site administrator to test the Fiery Central functionalities.
If the problems still exist on the FC integrated server, see the Troubleshooting sections of the user documentation.