Operation mode
Description
LCD display
Fault mode
Note:
*Fault mode: Errors are
caused by
inside circuit error
or external reasons such
as
over temperature, output
short circuit and so on.
System is not charging,
regardless of PV and grid/AC
power in being available.
Not charging.
Line Mode
The unit will provide output
power from the mains. It will
also charge the battery at
line mode.
Charging by utility and PV energy.
Charging by utility.
If “SUB” (solar first) is selected as output
source priority and solar energy is not
sufficient to power the load/s, solar energy
and the utility will provide the loads and
charge the battery at the same time.
Line Mode
The unit will provide output
power from the mains. It will
also charge the battery at
line mode.
If either “SUB” (solar first) or “SBU” is selected
as output source priority and battery is not
connected, solar energy and the utility
will power the load/s.
Power from utility.