41
Maximum discharging
current
Disable (Default)
If selected, battery discharge
protection is disabled.
30A
The setting range is from 30 A to
150 A. Increment of each click is
10A.
If discharging current is higher
than setting value, battery will stop
discharging. At this time, if the
utility is available, the inverter will
operate in bypass mode. If no
utility is available, the inverter will
shut down after 5-minute
operation in battery mode.
150A
51
On/Off control for RGB LED
*This setting must be
enable to activate RGB LED
lighting function.
Enabled (default)
Disable
52
Brightness of RGB LED
Low
Normal (default)
High
53
Lighting speed of RGB LED
Low
Normal (default)
EG4 Electronics