23. Programme unit
438 9145-41/03
03.11
PAUSE TEST LEVEL 0
PAUSE TEST TEMPERATURE -18 °C
DEFAULT TEMPERATURE HYSTERIS 4 °C
TEMPERATURE STEP IN COOL-DOWN 4 °C
DEFAULT LOW EXTRACT TIME 00:00
DEFAULT MEDIUM EXTRACT TIME 00:00
DEFAULT HIGH EXTRACT TIME 00:00
DEFAULT DRAIN TIME 00:00
DEFAULT DISTR. TIME 00:00
DO UNBALANCE MEASUREMENT N
DRAIN OPEN DELAY 0:13
START EXTRACT TIME 00:30
ROLLOUT TIME 00:01
PAY PER WASH ALARM 0
1 2 3
4 5 6
7 8 9
0
DEFAULT TEMPERATURE HYSTERIS 4°C
TEMPERATURE STEP IN COOL-DOWN 4 °C
DEFAULT LOW EXTRACT TIME 00:00
DEFAULT MEDIUM EXTRACT TIME 00:00
DEFAULT HIGH EXTRACT TIME 00:00
DEFAULT DRAIN TIME 00:00
DEFAULT DISTR. TIME 00:00
DO UNBALANCE MEASUREMENT N
DRAIN OPEN DELAY 0:13
START EXTRACT TIME 00:30
ROLLOUT TIME 00:01
PAY PER WASH ALARM 0
LOCK TEST DELAY 0:10
DRAIN TIME WHEN OVERFILL 0:05
Y/N
Default values for re-start after unbalance
Here you determine the drain time and distribution
time the machine will use if it cannot find the time
parameters it requires, e.g. during manual
operation of the drain in a washer extractor with a
suspended drum.
Unbalance measurement
Here you determine whether the machine will
calculate unbalance before it accelerates to
extraction speed. Drum unbalance can only be
calculated in washer extractors with suspended
drums. It uses torque data from the motor control
unit to determine whether the imbalance is too
high.
For washer extractors with suspended drums
without frequence control and which have a
separate unbalance switch, the answer to this
question should be No.
If you answer Yes (Y):
The machine will calculate unbalance before
every extraction sequence.
If you answer No (N):
The machine will not calculate unbalance.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Answer Yes (Y) or No (N).
Press .