Event
number
Event name Event description Event value (VALUE)
60 CU NTC SHORT The warning number 60 has occurred:
The CU temperature sensor is short circuited.
Not significant
61 CU NTC OPEN The warning number 61 has occurred:
The CU temperature sensor is open.
Not significant
62 HEAT PUMP FAULT The warning number 62 has occurred:
Indicates that the heat pump has generated an error.
Not significant
63 CU TEMP. HIGH The CU temperature has exceeded by 8°C/14°F degrees the
permissible max. value to ensure the correct operation of the
heat pump.
Indicates the CU temperature at the time of
event recording.
64 CU TEMP. LOW During the wash phase the CU temperature has decreased by
more than 10 °C/18 °F with respect to the permissible min. value
(–hysteresis temperature set point) to ensure the correct
operation of the heat pump.
Indicates the CU temperature at the time of
event recording.
65 LEV. LOW WASH Washing has stopped due to a lowering of the levels Indicates the air gap level at the time of
event recording.
66 RINSE FLOW CTRL A calibration cycle for the rinse flow shutter has been started. Whole part and fractional part of the flow
measured.
71 DT HEAT. TOUT Alarm number 71 has occurred:
The required temperature in the drying tunnel was not reached
within the max. heating time.
Indicates the drying tunnel temperature at
the time of event recording.
72 DT OVERTEMP. Alarm number 72 has occurred:
The temperature in the drying tunnel is too high.
Indicates the drying tunnel temperature at
the time of event recording.
73 DT NTC SHORT Alarm number 73 has occurred: ( Up to version FW 1.52)
The drying tunnel temperature sensor is short circuited.
Not significant
74 DT NTC OPEN Alarm number 74 has occurred:
The drying tunnel temperature sensor is open.
Not significant
75 DT FAN THER. Alarm number 75 has occurred:
The drying tunnel fan thermal protector has tripped.
Not significant
76 MOT CURR OOR H. Alarm number 76 has occurred:
The gear motor supplied current is higher than the maximum
value allowed for the gear motor current.
Not significant
77 MOT CURR OOR L. Alarm number 77 has occurred:
The gear motor supplied current is lower than the minimum value
allowed for the gear motor current.
Not significant
78 HIGH MOT. CURR. Dishes are jammed.:
The gear motor supplied current is higher than the value set in
the “Max motor curr.” parameter.
Indicates the supplied current to gear motor
at the time of event recording.
79 BOIL. USA T. HI. The first boiler temperature has exceeded the temperature set
point by 7 °C/13 °F.
Indicates the first boiler temperature at the
time of event recording.
80 BOIL. USA T. LO. During the wash phase the first boiler temperature has
decreased by more than 12 °C/25 °F with respect to the
permissible min. value (– hysteresis temperature set point).
Indicates the first boiler temperature at the
time of event recording.
81 EN. PEAK CTRL. The “Energy peak control” input has been activated. All the
heating elements of the machine remain off during activation of
this input.
Indicates the boiler temperature at the time
of event recording.
82 BOIL. USA TOUT Alarm number 82 has occurred:
The required temperature was not reached in the first boiler
within the max. heating time.
Indicates the first boiler temperature at the
time of event recording.
83 BOIL. USA OVERT. Alarm number 83 has occurred:
The water temperature in the first boiler is too high
Indicates the first boiler temperature at the
time of event recording.
84 BOIL. USA NTC S. Alarm number 84 has occurred:
The first boiler temperature sensor is short circuited.
Not significant
85 BOIL. USA NTC O. Alarm number 85 has occurred:
The first boiler temperature sensor is open.
Not significant
86 SEN. PRESS. ADJ The pressure sensor setting procedure has been performed. Not significant
89 U.I. TEMP. HIGH Alarm number 89 has occurred:
Temperature too high on User interface.
Indicates the User interface temperature at
the time of event recording.
90 ECAP ERROR Alarm number 90 has occurred:
Communication problems between machine electronic boards.
Indicates the module that generated a
communication error between User interface
and Mec:
1: rinse
2: wash
4: prewash
8: DT.