Event name Event description Event value (VALUE)
34 WASH OVERTEMP. Alarm number 34 has occurred:
The water temperature in the wash tank is too high.
Indicates the wash tank temperature at the
time of event recording.
35 WASH NTC SHORT Alarm number 35 has occurred:
The wash tank temperature sensor is short circuited.
Not significant
36 WASH NTC OPEN Alarm number 36 has occurred:
The wash tank temperature sensor is open.
Not significant
37 WASH PUMP1 THER. Alarm number 37 has occurred:
The upper wash pump thermal protector has tripped.
(short compact and modular machines only)
Not significant
38 WASH PUMP2 THER. Alarm number 38 has occurred:
The lower wash pump thermal protector has tripped.
(modular machines only)
Not significant
39 CU FAN THER. Alarm number 39 has occurred:
The CU (condensing unit) fan thermal protector has tripped.
(short compact and modular machines only)
Not significant
40 DRAIN WASH TOUT Alarm number 40 has occurred:
The wash tank was not completely emptied within the max.
emptying time.
Indicates the wash tank level at the time of
event recording.
42 AIRGAP LEV. LOW The air gap tank water level has fallen by more than 10 mm with
respect to the permissible min. level (–hysteresis set point level).
Indicates the air gap level at the time of
event recording.
43 DUO LEV. LOW The duo rinse tank water level has fallen by more than 10 mm
with respect to the permissible min. level (–hysteresis set point
level).
Indicates the duo rinse level at the time of
event recording.
44 WASH LEV. LOW The wash tank water level has fallen by more than 20 mm with
respect to the permissible min. level (–hysteresis set point level).
Indicates the wash tank level at the time of
event recording.
45 PREWASH LEV. LOW The prewash tank water level has fallen by more than 20 mm with
respect to the permissible min. level (–hysteresis set point level).
Indicates the prewash tank level at the time
of event recording.
46 POWER ON Records appliance activation. Not significant
47 FORCED WASH A wash start has been forced. Indicates the boiler temperature at the time
of event recording.
48 EMERGENCY
SWITCH
The emergency mushroom has been pressed. Not significant
49 PARAMETER MODE Parameter mode has been accessed. Not significant
50 PARAMETER MODIF. A parameter has been modified. Indicates the modified family and parameter
number.
51 PREW. FILL. TOUT Alarm number 51 has occurred:
The prewash tank was not completely filled within the max. filling
time.
Indicates the prewash tank level at the time
of event recording.
52 PREW. LEV. FAULT Alarm number 52 has occurred:
The pressure sensor on the prewash tank does not work
correctly.
Indicates the prewash tank level at the time
of event recording.
53 PREW. HEAT. TOUT Alarm number 53 has occurred:
The required temperature in the prewash tank was not reached
within the max. heating time.
Indicates the prewash tank temperature at
the time of event recording.
54 PREW. OVERTEMP. Alarm number 54 has occurred:
The water temperature in the prewash tank is too high.
Indicates the prewash tank temperature at
the time of event recording.
55 PREW. NTC SHORT Alarm number 55 has occurred:
The prewash tank temperature sensor is short circuited.
Not significant
56 PREW. NTC OPEN Alarm number 56 has occurred:
The prewash tank temperature sensor is open.
Not significant
57 PREW. PUMP THER. Alarm number 57 has occurred:
The prewash pump thermal protector has tripped.
Not significant
58 DRAIN PREW. TOUT Alarm number 58 has occurred:
The prewash tank was not completely emptied within the max.
emptying time.
Indicates the prewash tank level at the time
of event recording.

Table of Contents