5.4.1 Visibility of parameters and sub-menus
With a personal computer, interface key (copy card), suitable cables and the “Param Manager” software, it is possible to
restrict the visibility and modification of parameters and entire submenus.
A “visibility value” may be assigned to each parameter, as described below:
Value Meaning
0003 Parameter or label visible at all times
0258 Parameter or label visible if user password entered correctly (password = Pa
H46)
0770 Parameter or label visible if user password entered correctly (password = Pa
H46). Parameter cannot be modified.
0768 Parameter visible from PC only.
Some visibility settings are factory set.
For more information, please refer to the “Param Manager” instructions.