Elma Schmidbauer GmbH 12 Operating the unit
Elmasonic Select 25 / 32
Hold down the Select button (1) for >2seconds until the display shows all four
programme numbers (3) and programme number 1 flashes. Now, press one of the
Plus/minus buttons repeatedly until the programme number in which you wish to save
your settings flashes. Press the Select button (1) again briefly to confirm saving the
programme. The saved programme number (4) will be shown on the display.
12.10 Start a saved ultrasonic cleaning programme
At least one programme from a possible fourprogramme numbers has been saved.
The unit is in Programme mode. The last-used programme number is shown on the display.
The unit is in Normal mode. No programme number is shown on the display.
Press the Select button to switch between normal mode and programme mode. The
last-used programme number is shown in the programme mode e.g., programme
number 1.
Press one of the Plus/minus buttons to select a programme.
Press the Start/stop button to start the displayed programme.
The Remaining time and Heating symbols will be shown on the display (if saved). The
remaining time, the current temperature and the ultrasound mode are continuously
shown on the display.
IMPORTANT Depending on the settings saved in the programme, ultrasonic cleaning
is started with auto-degas (degas flashes) or Temperature-controlled start (only starts
once the target temperature has been reached). The respective symbols are shown on
the display.
The end of cleaning is indicated by the End of cleaning symbol and, where applicable,
an acoustic signal (depending on the parameter settings). The Remaining time display
will disappear.
12.11 Switch off and save
For information on saving programmes, see Save programmes.
The displayed settings are saved when the unit is switched off and are then available the next
time the unit is switched on. This function cannot be used to save auto-degas and Temperature-
controlled start.
Press the On/off button to switch off the unit. Any settings made will be saved until the