MES53xx, MES33xx, MES23xx Ethernet Switch Series 196
cost: (1..65535)/10
Specify the channel status metric that represents the “value”
of data transfer via the link.
Set the default value.
interval: (1..65535)
seconds
Set the time interval in seconds after which the neighbour will
be considered as “dead”. This interval must be a multiple of
hello-interval. As a rule, dead-interval equals 4 hello packet
intervals.
Set the default value.
interval: (1..65535)/10
seconds
Set the time interval in seconds after which the router sends
the next hello-package from the interface.
Set the default value.
-/disabled
Disable MTU verification.
Set the default value.
-
Set the IPv6 address of the neighbour.
Delete the IPv6 address of the neighbour.
priority: (0..255)/1
Assign priority of the router which is used for selection of DR
and BDR.
Set the default value.
interval: (1..65535)/5
seconds
Specify a time interval in seconds after which the router
resends a package for which it hasn’t received a delivery
confirmation (e.g. Database Description package or Link State
Request packages).
Set the default value.
delay: (1..65535)/1
seconds
Specify an approximate time in seconds required to transfer a
channel status packet.
Set the default value.
Privileged EXEC mode commands
Command line prompt in the Privileged EXEC mode is as follows:
console#
Table 5.232. Privileged EXEC mode commands
Command
Value/Default value
Action
show {ip | ipv6} ospf
[process_id]
process_id: (1..65536)
Display OSPF configurations.
show {ip | ipv6} ospf
[process_id] neighbor
process_id: (1..65536)
Display information about OSPF neighbours.
show ip ospf [process_id]
neighbor A.B.C.D
process_id: (1..65536);
A.B.C.D: neighbor IP
address
Display information about OSPF neighbours with a specific
address.
show {ip | ipv6} ospf
[process_id] interface
process_id: (1..65536)
Display configuration of all OSPF interfaces.
show {ip | ipv6} ospf
[process_id] interface
{gigabitethernet gi_port |
tengigabitethernet te_port |
fortygigabitethernet fo_port |
port-channel group |
vlan vlan_id |
tunnel tunnel_id}
process_id: (1..65535);
gi_port: (1..8/0/1..48);
te_port: (1..8/0/1..24);
fo_port: (1..8/0/1..4);
group: (1..16);
vlan_id: (1..4094);
tunnel_id: (1..16)
Display configuration of a specific OSPF interface.
show {ip | ipv6} ospf
[process_id] database
[router | summary |

process_id: (1..65535)
Display the status of an OSPF protocol database.
show {ip | ipv6} ospf
process_id]
process_id: (1..65535)
Display parameters and the current status of virtual links: