SBC session border controllers 17
2.5.1.2 SBC-2000
Light indication of the device in operation is shown in Table 9.
Table 9 Light indication of the device in operation
Indicator
Indicator State
Device Status
Alarm
flashes red
critical device failure
solid red
non-critical device failure
solid yellow
no failures, non-critical warnings
solid green
normal operation
Status
solid green
normal operation
off
device power lost
Sync.0, Sync.1
solid green
synchronization with an external source
off
external synchronization source disconnected
Power
solid green
powered by power supply unit #1
solid orange
power supply unit #1 is installed, not supplied with power
RPS
solid green
power supply unit #2 is installed, supplied with power
solid red
power supply unit #2 is installed, not supplied with power
off
power supply unit #2 is not installed
FAN
solid green
all removable fan modules are installed, all fans are
operational
solid orange
all removable fan modules are installed, some fans are
down
solid red
one or both removable fan modules are not installed
USB
solid green
USB flash is installed
off
USB flash is not installed
2.5.1.3 SBC-3000
Light indication of the device in operation is shown in Table 10.
Table 10 Light indication of the device in operation
Indicator
Indicator State
Device Status
Alarm
Flashes red
Critical device failure
Solid red
Non-critical device failure
Solid yellow
No failures, non-critical warnings
Solid green
Normal operation
Status
Solid green
Normal operation
Off
Device power lost
Sync.1, Sync.2
Solid green
Synchronization with an external source
Off
External synchronization source disconnected
Power
Solid green
Powered by power supply unit #1
Solid orange
Power supply #1 is installed, not supplied with power
RPS
Solid green
Power supply unit #2 is installed, supplied with power
Solid red
Power supply unit #2 is installed, not supplied with power
Off
Power supply unit #2 is not installed
FAN
Solid green
All removable fan modules are installed, all fans are
operational
Solid orange
All removable fan modules are installed, some fans are
down
Solid red
One or both removable fan modules are not installed
USB
Solid green
USB flash is installed
Off
USB flash is not installed