EM TEST Compact NX5
Operating Manual V 1.06 69 / 143
EFT Electrical Fast Transients Burst as per IEC 61000-4-4
200 V – 5500 V ± 10% Step 1 V
Wave shape into a 50 load
Wave shape into a 1000 load
0 - 360° (16 – 500 Hz)
Asynchronous = 0° a reference signal is connected to the Sync input.
1Hz – 1000 kHz Range Step
< 10 kHz 1 Hz
10 – 1000 kHz 1.0 kHz
1 s – 9999 s
1 min - 167 min
Direct via 50 coaxial connector
To connect ext. coupling devices
To L, N, PE all combinations
AC 300 V / 16 A / 50/60 Hz
Immediate start, all parameters adjustable during a running test
IEC 61000-4-4 level 1-4 to power lines
IEC 61000-4-4 level 1-4 to signal lines
EN 61000-6-1 Generic to power lines
EN 61000-6-1 Generic to signal lines
EN 61000-6-2 Generic to power lines
EN 61000-6-2 Generic to signal lines
IEC 61000- 4-4 Manual operated standard test routine
Voltage iteration stepwise: Voltage level V after n pulses by V
Frequency sweep in one single burst
Frequency sweep with constant pulse numbers
Frequency sweep, constant burst duration
Synchronized with phase angle
* With Burst pulses as per. IEC 61000-4-4 Ed 3: 2012 the max. output voltage with external CDN can be limited.