SURGE Immunity requirements as per IEC 61000-4-5
Test Level
compact NX5 (16A Models)
compact NX5 (32 A Models)
Open circuit voltage
160 V 5000 V ± 10% Step 1 V
Short circuit current
80 A 2500 A ± 10%
Wave shape open circuit
coupling
18 F line to line 9 F line to ground
18 F line to line 9 F line to ground
Front time tr
1,2 s ± 30% 1,2 s ± 30%
1,2 s ± 30% 1,2 s ± 30%
Pulse duration
50 s +10 μs/-10 μs 50 s +10 μs/-25 μs
50 μs +10 μs/-15 μs 50 μs +10 μs/-30 μs
Wave shape short circuit
coupling
18 F line to line 9 F line to ground
Front time tr
8 s ± 20% 2.5 s ± 30%
Pulse duration
20 s ± 20% 25 s ± 30%
Polarity
Pos., Neg., Alt
Repetition rate
max. 1 Hz (1 s* - 9999 s)
Events preselection
1 - 99'999
Counter
1 1000’000
Trigger
Trigger of pulses
AUTO, MAN, EXTERN
Synchronization
0 - 360° (16 500 Hz)
Asynchronous = 0° a reference signal is connected to the Sync input.
Resolution
Measurements
CRO
5 V Trigger
CRO Û
10 Vp at 5 kV
CRO Î
10 Vp at 2.5 kA
Accuracy CRO V , CRO I
± 10%
CRO Û/I Z measuring instrument
> 1 M
Peak voltmeter
5000 V
Peak current meter
2500 A: Display 1 Digit 20 A
Current limiter setting
10 A...3000 A step 10 A
Output
no
9 F
18 F
Direct HV-COM
HV-Banana connector, Zi = 2
x
x
Coupling network
L N with Z = 2
x
L-PE, N-PE, L+N-PE with Z = 12
x
DUT supply
AC 300 V / 16 A / 50/60 Hz
DC 300 V / 16 A
Test Routines
Quick Start
Immediate start, all parameters adjustable during a running test
Standard test routines
IEC 61000-4-5 one level: Selectable level 1 to 4
separated to (AC / DC)
IEC 61000-4-5 all levels: Starts from lowest level to selected level
IEC 61000-4-5 level 3
IEC 61000-4-5 level 4
EN 61000-6-1 Generic (AC / DC)
EN 61000-6-2 Generic
Extended Tests
Voltage iteration stepwise: Voltage level V after n pulses by V
Angle iteration stepwise: Change phase angle A after n pulses by A
Angle random iteration: Random phase angle A after n pulses
* depends on charging voltage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EM TEST compact NX5 Series and is the answer not in the manual?

EM TEST compact NX5 Series Specifications

General IconGeneral
BrandEM TEST
Modelcompact NX5 Series
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals