EM Test CWS500 D
User manual V 1.07 30 / 34
Interfaces
Serial RS 232 Baudrate 1200 - 19600 baud
Parallel IEEE 488 GPIB interface Addresses 1 - 30 selectable
All interfaces are included as standard features.
Powermeter PM 1000
Frequency range 10kHz – 1000 MHz
Input range Monitor -45 dBm ... +13 dBm
FWD power -50 dBm ... +13 dBm
REV power -50 dBm ... +13 dBm
Max. Input MONITOR 13dBm approx. 1.3 Vrms
Accuracy < ± 0.5 dB ( 0.1MHz...400MHz )
< ± 1.0 dB ( 0.01MHz...1000MHz )
Bi directional coupler
Frequency range 10 kHz .. 1000MHz
Power (maximum) 200Watt
Coupling factor 40 dB
Directivity 25 dB typical
Insertion loss 0.5 dB
VSWR 1.25 maximum
RF Amplifier ( built in )
Frequency range 10 kHz .. 400 MHz
Nominal 10kHz .. 400 MHz min. 80 Watt ( min. 49dBm )
Gain approx. 52dB
General data
Dimensions ( HxWxD) 19"/6HE (286 x 450 x 500) mm
Weight approx. 31.5kg
Power supply 110-230V/ max 50/60Hz
Input power max. 380W
Power factor cosφ=0,98 at max output power acc. to IEC 555
Fuse 2x6,3AT (115V / 230V)
Cooling active cooling, air ventilation
Environment conditions 10°C - 40°C
Humidity Max. rel. humidity 80% up to 31°C Decreasing linearly to 50% at 40°C
=>> Non compulsory specification, may be subject to change <<=