EasyManua.ls Logo

EM TEST CWS 500D - Page 30

EM TEST CWS 500D
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EM Test CWS500 D
User manual V 1.07 30 / 34
Interfaces
Serial RS 232 Baudrate 1200 - 19600 baud
Parallel IEEE 488 GPIB interface Addresses 1 - 30 selectable
All interfaces are included as standard features.
Powermeter PM 1000
Frequency range 10kHz – 1000 MHz
Input range Monitor -45 dBm ... +13 dBm
FWD power -50 dBm ... +13 dBm
REV power -50 dBm ... +13 dBm
Max. Input MONITOR 13dBm approx. 1.3 Vrms
Accuracy < ± 0.5 dB ( 0.1MHz...400MHz )
< ± 1.0 dB ( 0.01MHz...1000MHz )
Bi directional coupler
Frequency range 10 kHz .. 1000MHz
Power (maximum) 200Watt
Coupling factor 40 dB
Directivity 25 dB typical
Insertion loss 0.5 dB
VSWR 1.25 maximum
RF Amplifier ( built in )
Frequency range 10 kHz .. 400 MHz
Nominal 10kHz .. 400 MHz min. 80 Watt ( min. 49dBm )
Gain approx. 52dB
General data
Dimensions ( HxWxD) 19"/6HE (286 x 450 x 500) mm
Weight approx. 31.5kg
Power supply 110-230V/ max 50/60Hz
Input power max. 380W
Power factor cosφ=0,98 at max output power acc. to IEC 555
Fuse 2x6,3AT (115V / 230V)
Cooling active cooling, air ventilation
Environment conditions 10°C - 40°C
Humidity Max. rel. humidity 80% up to 31°C Decreasing linearly to 50% at 40°C
=>> Non compulsory specification, may be subject to change <<=