260
Celerra Network Server Command Reference Manual
The nas Commands
raid_type = RAID5
logical_capacity = 1068997528
num_spindles = 5 - 0_0_0 0_0_1 0_0_2 0_0_3 0_0_4
num_luns = 6 - 0000 0001 0002 0003 0004 0005
num_disk_volumes = 6 - root_disk root_ldisk d3 d4 d5 d6
spindle_type = FC
bus = 0
raw_capacity = 1336246910
used_capacity = 62914560
free_capacity = 1006082968
hidden = False
<...removed...>
id = 2_0_14
product = ST314670 CLAR146
revision = 6A06
serial = 3KS02RHM
capacity = 280346624
used_capacity = 224222822
disk_group = 0014
hidden = False
type = FC
bus = 2
enclosure = 0
slot = 14
vendor = SEAGATE
remapped_blocks = -1
state = ENABLED
For the Celerra Network Server with a Symmetrix backend, to
display information for the attached storage system, type:
$ nas_storage -info 000187940260
id = 1
serial_number = 000187940260
name = 000187940260
type = Symmetrix
ident = Symm6
model = 800-M2
microcode_version = 5670
microcode_version_num = 16260000
microcode_date = 03012004
microcode_patch_level = 69
microcode_patch_date = 03012004
symmetrix_pwron_time = 1130260200 == Tue Oct 25 13:10:00 EDT 2005
db_sync_time = 1133215405 == Mon Nov 28 17:03:25 EST 2005
db_sync_bcv_time = 1133215405 == Mon Nov 28 17:03:25 EST 2005
db_sync_rdf_time = 1133215405 == Mon Nov 28 17:03:25 EST 2005
last_ipl_time = 1128707062 == Fri Oct 7 13:44:22 EDT 2005
last_fast_ipl_time = 1130260200 == Tue Oct 25 13:10:00 EDT 2005
API_version = V6.0-629