Celerra Network Server Command Reference Manual
The fs Commands
-info [<fs_name>|id=<fs_id>]
Displays information for the specified Celerra FileMover file systems.
-modify {<fs_name>|id=<fs_id>}
Sets Celerra FileMover parameters for the specified file system.
Note: When specifying the -modify option on a disabled file system, the state
is automatically changed to enabled. To maintain the disabled state, specify
-state disabled.
[-state {enabled|disabled}]
Enables and disables Celerra FileMover operations on the
specified file system. The file system must be enabled to accept
other options. When disabled, previous options are remembered
by the file system when enabled again.
[-popup_timeout <sec>]
Specifies the Windows popup timeout value in seconds. If a CIFS
I/O request cannot be processed within the specified time, then a
popup notification of the delay is sent to the CIFS client. The
default for <sec> is 0 (zero) which disables Windows popups.
Note: It may take up to 10 seconds before the popup is displayed.
[-backup {offline|passthrough}]
Specifies the nature of CIFS network backups. The offline option
backs up the stub file only. The passthrough (default) option
backs up all of the file data via passthrough read.
[-log {on|off}]
Enables or disables Celerra FileMover logging. The default log
filename is dhsm.log; it resides in the /.etc directory on the
FileMover-enabled file system.
[-max_log_size <mb>]
Specifies the maximum size of the logfile. The current logfile, in
addition to four old logfiles, are saved. The minimum log file size
is 10 MB.
[-offline_attr {on|off}]
Specifies whether the Data Mover should set the CIFS offline file
attributes on the stub files. The default is on.

Table of Contents

Other manuals for EMC Celerra

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC Celerra and is the answer not in the manual?

EMC Celerra Specifications

General IconGeneral
BrandEMC
ModelCelerra
CategoryServer
LanguageEnglish

Related product manuals