server_param
433
The server Commands
paxReadBuff PAX 64 64
filter.numDirFilter PAX 5 5
noFileStreams PAX 0 0
nFTSThreads PAX 8 8
scanOnRestore PAX 1 1
filter.caseSensitive PAX 1 1
nPrefetch PAX 8 8
nRestore PAX 16 16
writeToArch PAX 1 1
writeToTape PAX 1 1
nThread PAX 64 64
Where:
If the value for the current and configured differ, refer to the
user_action field of the -info.
EXAMPLE #3 To view information on the nThread parameter, type:
$ server_param server_2 -facility PAX -info nThread
server_2 :
name = nThread
facility_name = PAX
default_value = 64
current_value = 64
configured_value =
user_action = none
change_effective = immediate
range = (1,128)
description = Number of worker threads per backup session
Where:
EXAMPLE #4 To modify the configured nThread parameter, type:
$ server_param server_2 -facility PAX -modify nThread -value 32
server_2 : done
Value Definition
name name of the parameters with the specified facility that can be modified.
facility facility for the parameters.
default default value for the parameter.
current current value used by the Data Mover.
configured value set that has not taken effect yet because some user action (such as a Data Mover reboot) is
required.
Value Definition
facility_name
facility for the parameter.
default_value
default value set for the parameter.
current_value
value set on the Data Mover.
configured_value
value set that has not taken effect yet because user action (such as a Data Mover reboot) is required.
user_action
action necessary for the parameter to take effect.
change_effective
states when the change will be effective.
range
range of possible parameter values.
description
description of what the parameter does.