mA Output 1: Mass Flow Rate
Postrequisites
If you change the configuration of mA Output Source, verify the settings of Lower Range Value and Upper
Range Value. The transmitter automatically loads a set of values, and these values may not be appropriate for
your application.
Options for mA Output Source
The transmitter provides a basic set of options for mA Output Source, plus several application-specific
options. Different communications tools may use different labels for the options.
Process variable Label
Display ProLink III FC
Standard
Mass flow rate Mass Flow Rate Mass Flow Rate Mass Flow Rate
Volume flow rate Volume Flow Rate Volume Flow Rate Volume Flow Rate
Gas standard volume flow
rate
GSV Flow Rate Gas Standard Volume Flow
Rate
Gas Standard Volume Flow
Temperature Temperature Temperature Temperature
Density Density Density Density
External pressure External Pressure External Pressure External pressure
External temperature External Temperature External Temperature External temperature
Diagnostics
Velocity Velocity Velocity Approximate Velocity
Two-phase flow detection Phase Phase Flow Severity Two-Phase Flow Detection
Drive gain Drive Gain Drive Gain Drive Gain
API referral
Temperature-corrected
density
Referred Density Density at Reference
Temperature
Density at Reference
Temperature
Temperature-corrected
(standard) volume flow rate
Referred Volume Flow Volume Flow Rate at
Reference Temperature
Referred Volume Flow Rate
Average temperature-
corrected density
Average Line Density Average Density Average Observed Density
Average temperature Average Temperature Average Temperature Average Temperature
Concentration measurement
Density at reference Referred Density Density at Reference
Temperature
Dens at Ref (CM)
Specific gravity Specific Gravity Density (Fixed SG Units) Spec Gravity (CM)
Standard volume flow rate Standard Vol Flow Volume Flow Rate at
Reference Temperature
Stnadard Volume Flow Rate
Net mass flow rate Net Mass Flow Net Mass Flow Rate Net Mass Flow (CM)
Configuration and Use Manual Integrate the meter with the control system
MMI-20048166 April 2019
Configuration and Use Manual 95

Table of Contents