EasyManua.ls Logo

Emerson Rosemount 702 - 2 Wireless considerations; 2.1 Power up sequence; 2.2 Antenna position; 2.3 Conduit entry

Emerson Rosemount 702
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Wireless considerations
2.1 Power up sequence
The Wireless Gateway should be installed and functioning properly before
any wireless field devices are powered. Install the Power Module,
SmartPower
Solutions model number 701PBKKF into the Rosemount 702
Transmitter to power the device. Wireless devices should be powered up in
order of proximity from the Gateway, beginning with the closest device,
then working outward from the Gateway. This results in a simpler and faster
network formation. Enable Active Advertising on the Gateway to ensure new
devices are able to join the network faster. For more information see the
Emerson Wireless 1410S Gateway.
2.2 Antenna position
The antenna should be positioned vertically, either straight up or straight
down, and it should be approximately 3 ft. (1 m) from any large structure,
building, or conductive surface to allow for clear communication to other
devices.
Figure 2-1: Antenna Position
2.3 Conduit entry
Upon installation, ensure each conduit entry is either sealed with a conduit
plug using approved thread sealant, or has an installed conduit fitting or
cable gland with appropriate threaded sealant.
Quick Start Guide April 2021
4 Emerson.com/Rosemount

Table of Contents

Other manuals for Emerson Rosemount 702